- Clean all of the oil pump
parts in solvent.
 
- Inspect the pump cover housing for the following conditions:
 
| •  | Porous or damaged casting | 
 
| •  | Excessive wear or galling | 
 
- Inspect the pressure relief valve for damage. Replace the valve
if the valve is damaged.
 
- Inspect the gerotor for the following conditions:
 
- Measure the following
parts:
 
| •  | The gerotor cavity depth | 
 
| •  | The inner gerotor tip clearance | 
 
| •  | The outer gerotor diameter clearance | 
 
- Replace the pump as an assembly if the housing or gears are worn
beyond specifications.