Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | 
 Does the test light?  | --  | Go to Step 3  | Go to Step 2  | 
2  | Locate and Repair the open BLK (1350) wire between component and ground. Is the action complete?  | --  | System OK  | --  | 
3  | Connect a self-powered test lamp from terminal B to ground at the Load Leveling Air Direction Valve. Does the test light?  | --  | Go to Step 4  | Go to Step 2  | 
4  | 
 Does the Load Leveling Pump run?  | --  | Go to Step 5  | Go to Step 6  | 
5  | Replace the Load Leveling Inflator Switch. Is the action complete?  | --  | System OK  | --  | 
6  | 
 Does the Load Leveling Pump run?  | --  | Go to Step 8  | Go to Step 7  | 
7  | Locate and Repair the open YEL (321) wire between the Load Leveling Timer Relay and Splice S472. Is the action complete?  | --  | System OK  | --  | 
8  | 
 Does the test lamp light?  | --  | Go to Step 12  | Go to Step 9  | 
9  | 
 Does the test lamp light?  | --  | Go to Step 10  | Go to Step 11  | 
10  | Locate and Repair the open DK BLU (1249) wire. Is the action complete?  | --  | System OK  | --  | 
11  | Replace the Load Leveling Timer Relay. Is the action complete?  | --  | System OK  | --  | 
12  | Using a DMM, (J39200), measure the resistance of the Load Leveling Air Direction Valve. Is the resistance within the value indicated?  | 20 - 100 ohms  | Go to Step 14  | Go to Step 13  | 
13  | Replace the Load Leveling Air Direction Valve. Is the action complete?  | --  | System OK  | --  | 
14  | 
 Does the test lamp light?  | --  | Go to Step 15  | Go to Step 11  | 
15  | Locate and Repair the PPL (1267) wire for a short to ground. Is the action complete?  | --  | System OK  | --  |