Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | 
 Does the Load Leveling Pump stop running?  | --  | Go to Step 2  | Go to Step 7  | 
2  | Connect a self-powered test lamp from terminal F, BLK (1250) at the Load Leveling Timer Relay to ground. Does the test lamp light?  | --  | Go to Step 3  | Go to Step 6  | 
3  | 
 Does the test lamp light?  | --  | Go to Step 4  | Go to Step 5  | 
4  | Locate and Repair the BLK (1250) wire for a shore to ground Is the action complete?  | --  | System OK  | --  | 
5  | Replace the Load Leveling Air Inflator Switch. Is the action complete?  | --  | System OK  | --  | 
6  | Replace the Load Leveling Timer Relay. Is the action complete?  | --  | System OK  | --  | 
7  | Disconnect the Load Leveling Height Sensor. Does the Load Leveling Pump stop running?  | --  | Go to Step 8  | Go to Step 9  | 
8  | Replace the Load Leveling Height Sensor. Is the action complete?  | --  | System OK  | --  | 
9  | 
 Does the test lamp light?  | --  | Go to Step 10  | Go to Step 11  | 
10  | Locate and Repair the YEL (321) wire for a short to ground. Is the action complete?  | --  | System OK  | --  | 
11  | Replace the Load Leveling Pump. Is the action complete?  | --  | System OK  | --  |