Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Was the Driver Information Center System Check performed?  | --  | Go to Step 2  | |
2  | 
 Does the driver information center (DIC) display SC?  | --  | Go to Step 3  | Go to Step 8  | 
3  | 
 Does CKT 735 show a value within the specified range?  | 0-3 ohms  | Go to Step 4  | Go to Step 5  | 
4  | Repair the short to ground in CKT 735 between the DIC connector terminal 8 and the ambient air sensor terminal B. Is the repair complete?  | --  | --  | |
5  | Inspect the DIC connector for a poor connection. Are the connections OK?  | --  | Go to Step 7  | Go to Step 6  | 
6  | Repair the DIC connections as necessary. Is the repair complete?  | --  | --  | |
7  | Replace the DIC. Refer to Driver Information Center Replacement . Is the repair complete?  | --  | --  | |
8  | Inspect the ambient air temperature sensor connector for damage. Is the connector damaged?  | --  | Go to Step 9  | Go to Step 10  | 
9  | Repair the ambient air temperature sensor connections as necessary. Is the repair complete?  | --  | --  | |
10  | Replace the ambient air temperature sensor. Refer to Ambient Air Temperature Gage Sensor Replacement . Is the repair complete?  | --  | --  | 
Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Was the Driver Information Center System Check performed?  | --  | Go to Step 2  | |
2  | 
 Does the driver information center (DIC) display SC?  | --  | Go to Step 3  | Go to Step 8  | 
3  | 
 Does CKT 735 show a value within the specified range?  | 0-3 ohms  | Go to Step 4  | Go to Step 5  | 
4  | Repair the short to ground in CKT 735 between the DIC connector terminal 8 and the ambient air sensor terminal B. Is the repair complete?  | --  | --  | |
5  | Inspect the DIC connector for a poor connection. Are the connections OK?  | --  | Go to Step 7  | Go to Step 6  | 
6  | Repair the DIC connections as necessary. Is the repair complete?  | --  | --  | |
7  | Replace the DIC. Refer to Driver Information Center Replacement . Is the repair complete?  | --  | --  | |
8  | Inspect the ambient air temperature sensor connector for damage. Is the connector damaged?  | --  | Go to Step 9  | Go to Step 10  | 
9  | Repair the ambient air temperature sensor connections as necessary. Is the repair complete?  | --  | --  | |
10  | Replace the ambient air temperature sensor. Refer to Ambient Air Temperature Gage Sensor Replacement Is the repair complete?  | --  | --  |