Step  | Action  | Value(s)  | Yes  | No  | ||||
|---|---|---|---|---|---|---|---|---|
1  | Did you perform the Charging System Check?  | --  | Go to Charging System Check  | |||||
2  | Using the scan tool, inspect for any DTCs. Are any DTCs present?  | --  | Go to the Appropriate DTC  | |||||
3  | 
 Do all of the indicator bulbs turn ON and OFF properly?  | --  | Go to Instrument Cluster System Check in Instrument Panel, Gauges and Console  | |||||
4  | Disconnect the generator connector. Is the battery indicator still ON?  | --  | ||||||
5  | 
 
 
 Is continuity present?  | --  | ||||||
6  | Repair the short to ground. Is the repair complete?  | --  | Go to Charging System Check  | --  | ||||
7  | Using the J 39200 DMM, measure the voltage at the battery stud on the generator. Is the voltage within the specified range?  | 9-16 V  | ||||||
8  | Repair or replace the generator. Is the repair complete?  | --  | Go to Charging System Check  | --  | ||||
9  | Repair the open in CKT 2 (RED). Is the repair complete?  | --  | Go to Charging System Check  | --  |