Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the Lighting Systems Diagnostic System Check?  | --  | Go to Step 2  | |
2  | Verify that the high mount stoplamp is inoperative. Does the high mount stoplamp operate normally?  | --  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | Go to Step 3  | 
3  | 
 Does the test lamp illuminate at any of the test points?  | --  | Go to Step 5  | Go to Step 4  | 
4  | Locate and repair the open, high resistance or short to ground in CKT 17 (WHT). Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | Go to Step 10  | --  | 
5  | 
 Does the test lamp illuminate?  | --  | Go to Step 7  | Go to Step 6  | 
6  | Locate and repair the open, high resistance, or short to ground in CKT 1320 (LT BLU). Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | Go to Step 10  | --  | 
7  | 
 Does the test lamp illuminate?  | B+  | Go to Step 8  | Go to Step 9  | 
8  | Replace the high mount stoplamp. Refer to High Mount Stop Lamp Replacement . Is the repair complete?  | --  | Go to Step 10  | --  | 
9  | Locate and repair the open or high resistance in CKT 1850 (BLK) or 1350 (BLK). Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | Go to Step 10  | --  | 
10  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 3  |