Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the Instrument Cluster Diagnostic System Check?  | --  | Go to Step 2  | |
2  | Verify that the instrument cluster is inoperative. Does the instrument cluster operate normally?  | --  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | Go to Step 3  | 
3  | 
 Does the test lamp illuminate?  | --  | Go to Step 4  | Go to Step 8  | 
4  | Using a test lamp, test between the ignition 1 voltage circuit and the ground circuit (terminal A9). Refer to Circuit Testing in Wiring Systems. Does the test lamp illuminate?  | --  | Go to Step 5  | Go to Step 7  | 
5  | Using a test lamp, test between the ignition 3 voltage circuit and a good ground. Refer to Circuit Testing in Wiring Systems. Does the test lamp illuminate?  | --  | Go to Step 9  | Go to Step 6  | 
6  | Repair the open, high resistance or short to ground in the ignition 3 voltage circuit. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?  | --  | Go to Step 10  | --  | 
7  | Repair the open or high resistance in the ground circuit. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?  | --  | Go to Step 10  | --  | 
8  | Repair the open, high resistance or short to ground in the ignition 1 voltage circuit. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?  | --  | Go to Step 10  | --  | 
9  | Replace the instrument cluster. Refer to Instrument Cluster Replacement . Did you complete the replacement?  | --  | Go to Step 10  | --  | 
10  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 3  |