| Table 1: | HVAC Control Module Scan Tool Output Controls | 
| Table 2: | PCM Scan Tool Output Controls | 
Scan Tool Output Control  | Additional Menu Selection(s)  | Description  | 
|---|---|---|
A/C LED  | Miscellaneous Test  | The HVAC control module illuminates the A/C indicator LED when you select ON. The LED should remain illuminated until commanded OFF.  | 
A/C Request  | Miscellaneous Test  | The HVAC control module sends an A/C request signal to the PCM when you select ON. The PCM should energize the A/C compressor clutch relay. The A/C compressor clutch relay should remain energized until commanded OFF.  | 
Blower Motor  | Miscellaneous Test  | The HVAC control module commands the blower motor on to maximum speed when you select ON. The blower motor should operate at maximum speed until commanded OFF.  | 
Mix Motor  | Miscellaneous Test  | The HVAC control module commands the air temperature actuator towards 255 counts when you select ON. The HVAC control module commands the air temperature actuator towards 0 counts when commanded OFF.  | 
Select Solenoid 1  | Solenoid Test  | The HVAC control module energizes the defroster solenoid when you select ON. The solenoid should remain energized until commanded OFF. Blower motor operation is disabled during this test.  | 
Select Solenoid 2  | Solenoid Test  | The HVAC control module energizes the heater solenoid when you select ON. The solenoid should remain energized until commanded OFF. Blower motor operation is disabled during this test.  | 
Select Solenoid 3  | Solenoid Test  | The HVAC control module energizes the solenoid when you select ON. The solenoid should remain energized until commanded OFF. Blower motor operation is disabled during this test.  | 
Select Solenoid 4  | Solenoid Test  | The HVAC control module energizes the air inlet solenoid when you select ON. The solenoid should remain energized until commanded OFF. Blower motor operation is disabled during this test.  | 
Select Solenoid 5  | Solenoid Test  | The HVAC control module energizes the A/C solenoid when you select ON. The solenoid should remain energized until commanded OFF. Blower motor operation is disabled during this test.  | 
Scan Tool Output Control  | Additional Menu Selection(s)  | Description  | 
|---|---|---|
A/C Relay  | Engine Output Controls  | The PCM energizes the A/C compressor clutch relay when you select ON. The A/C compressor clutch should remain engaged until commanded OFF.  |