Step  | Action  | Yes  | No  | 
|---|---|---|---|
1  | Turn the blower motor fan ON and select an air outlet mode. Does air flow out of the selected HVAC outlet ducts?  | Go to Step 19  | Go to Step 2  | 
2  | Did the customer concern mention that the air discharges out the correct ducts at first, but then changes during higher engine RPM?  | Go to Step 11  | Go to Step 3  | 
3  | Cycle the HVAC controls through all the modes. Does the air come out of the selected outlet ducts now?  | Go to Step 19  | Go to Step 4  | 
4  | 
 Is there engine vacuum?  | Go to Step 5  | Go to Step 18  | 
5  | Take a vacuum reading at the vacuum supply line at the HVAC control solenoid. Is the vacuum reading the same as engine vacuum?  | Go to Step 6  | Go to Step 9  | 
6  | Take a vacuum reading at the output side of the HVAC control solenoid, for the non-functioning mode setting. Is there vacuum at the output side of the HVAC control solenoid?  | Go to Step 7  | Go to Step 14  | 
7  | Disconnect the actuator vacuum line and apply vacuum to the actuator. Did the actuator retract?  | Go to Step 9  | Go to Step 8  | 
8  | With the actuator disconnected, inspect the door for binding. Does the door move freely?  | Go to Step 10  | Go to Step 16  | 
9  | Inspect for leaking or collapsed vacuum lines. Are the vacuum lines leaking?  | Go to Step 17  | Go to Step 13  | 
10  | Replace the vacuum actuator. Refer to the appropriate procedure: Is the repair complete?  | Go to Step 19  | --  | 
11  | With the vacuum gage connected to the actuator vacuum line, turn the engine OFF. Does the system lose vacuum after turning OFF the engine?  | Go to Step 12  | Go to Step 9  | 
12  | 
 Does the system lose vacuum after turning OFF the engine?  | Go to Step 13  | Go to Step 14  | 
13  | Replace the vacuum reservoir tank. Refer to Vacuum Tank Replacement . Is the repair complete?  | Go to Step 19  | --  | 
14  | Test the operation of the HVAC vacuum control solenoid. Refer to Air Delivery Improper . Is the control solenoid operating properly?  | Go to Step 19  | Go to Step 15  | 
15  | Replace the vacuum control assembly. Refer to Vacuum Control Assembly Replacement . Is the repair complete?  | Go to Step 19  | --  | 
16  | Repair or replace the binding door. Refer to the appropriate procedure: Is the repair complete?  | Go to Step 19  | --  | 
17  | Repair or replace the collapsed or leaking vacuum line. Is the repair complete?  | Go to Step 19  | --  | 
18  | Repair the no vacuum condition. Is the repair complete?  | Go to Step 19  | --  | 
19  | Cycle the HVAC controls through all modes to verify proper operation. Did you correct the condition?  | System OK  | --  |