Step
| Action
| Value(s)
| Yes
| No
|
1
|
- Disconnect the generator connector.
- Turn the ignintion switch to the RUN position.
- Using the DMM, measure the voltage between terminal F of the generator
connector and a known good ground.
Is the voltage reading within the specified range?
| B+
|
Go to Step 3
|
Go to Step 2
|
2
| Locate and repair an open or a high resistance in CKT 41.
Is the repair complete?
| --
|
Go to Step 8
| --
|
3
| Using the DMM, measure the voltage from the BAT terminal of the generator
to a known good ground.
Is the voltage reading within the specified range?
| B+
|
Go to Step 5
|
Go to Step
|
4
| Locate and repair an open or a high resistance in CKT1.
Is the repair complete?
| --
|
Go to Step 8
| --
|
5
|
- Connect the generator.
- Turn all accessories OFF.
- Run the engine at fast idle.
- Using the DMM, measure the voltage across the battery.
Is the voltage reading within the specified range?
| 13.5-15.5 V
|
Go
to Step 7
|
Go to Step 6
|
6
| Repair or replace the generator. Refer to
Generator Replacement
.
Is the repair or replacement complete?
| --
|
Go to Step 8
| --
|
7
|
- Load test the generator. Refer to
Generator Assembly Check
.
- If the generator is OK, replace the battery. Refer to
Battery Replacement
.
| --
|
Go to Step 8
| --
|
8
|
- Connect all connectors and components that were disconnected.
- Verify that the charging circuit works properly.
Does the charging circuit work properly?
| --
| System is OK
|
Go to Step 1
|