Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: Engine Cooling Schematics . Connector End View Reference: Component Connector End Views . DEFINITION: One or both engine cooling fan motors run continuously in high or low speed.  | |||
1  | Did you perform the Diagnostic System Check - Vehicle?  | Go to Step 2  | |
2  | Ignition ON, engine OFF. Are both cooling fans operating at low speed?  | Go to Step 4  | Go to Step 3  | 
3  | Is the left cooling fan operating at high speed?  | Go to Step 5  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.  | 
4  | Remove the low speed fan relay. Did the fans turn OFF?  | Go to Step 6  | Repair the cooling fan motor supply voltage circuit of the right cooling fan for a short to voltage. Refer to Wiring Repairs .  | 
5  | Remove the high speed fan relay. Did the left cooling fan turn OFF?  | Go to Step 7  | Repair the cooling fan motor supply voltage circuit of the left cooling fan for a short to voltage. Refer to Wiring Repairs .  | 
6  | Inspect for poor connections at the low speed fan relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | System OK  | Replace the low speed fan relay.  | 
7  | Inspect for poor connections at the high speed fan relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | System OK  | Replace the high speed fan relay.  |