Tools Required
 
J-34142-A 
 Unpowered Test
Light.
Notice: Refer to Test Probe Notice in the Preface section.
A test lamp can simply and quickly test a low impedance circuit for voltage.
The J34142-B Unpowered Test Light is comprised of a 12-volt light bulb with
an attached pair of leads.
To correctly operate this tool use the following procedures.
When testing for voltage:
- Attach one lead of the 
J-34142-A 
 to ground.
 
- Touch the other lead of the 
J-34142-A 
to various points along the circuit where voltage should be present.
 
-  When the bulb illuminates, there is voltage at the point being tested.
 
When testing for ground:
- Attach one lead of the 
J-34142-A 
 to battery positive voltage.
 
- Touch the other lead of the 
J-34142-A 
 to various points along the circuit where ground should be present.
 
- When the bulb illuminates, there is ground at the point being tested.