Step  | Action  | Values  | Yes  | No  | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics . Connector End View Reference: Component Connector End Views . DEFINITION: The temperature cannot be adjusted, or heating is insufficient.  | ||||||||||||||||
1  | Did you perform the Diagnostic System Check - Vehicle?  | --  | Go to Step 2  | |||||||||||||
2  | Check operation of air mix doors to make sure they are not jammed or broken Is the air mix door broken or jammed?  | -  | Go to HVAC Module Assembly Replacement .  | Go to Step 3  | ||||||||||||
3  | Place the blower motor switch in each speed position. Does the blower motor operate in any speed position?  | --  | Go to Step 4  | Go to Blower Motor Inoperative .  | ||||||||||||
4  | Does the blower motor operate at the desired speeds?  | --  | Go to Step 5  | Go to Blower Motor Malfunction .  | ||||||||||||
5  | 
 Does the recirculation door move from the recirculation position to the outside air position?  | --  | Go to Step 6  | Go to Air Recirculation Malfunction .  | ||||||||||||
6  | Place the passenger temperature switch in the OFF position. Does the Too Cold in vehicle condition occur when heating or defrosting is desired?  | --  | Go to Step 7  | Go to Step 9  | ||||||||||||
7  | 
 Does the A/C compressor operate?  | --  | Go to Step 8  | |||||||||||||
8  | Inspect the cooling system for the following conditions: 
 
 
 
 
 
 Refer to Heating Performance Diagnostic . Did you find and correct the condition?  | --  | Go to Step 24  | Go to Step 9  | ||||||||||||
9  | 
 Does the paper stay in place?  | --  | Go to Step 10  | Go to Step 17  | ||||||||||||
10  | 
 Does the scan tool indicate the sensor temperatures is within 3°C (5°F) of the thermometer temperature?  | --  | Go to Step 11  | Go to Step 14  | ||||||||||||
11  | 
 Is the Sunload Sensor parameter greater than the specified value?  | 220 Counts  | Go to Step 12  | Go to Step 18  | ||||||||||||
12  | 
 Do the counts change?  | --  | Go to Step 13  | Go to Step 18  | ||||||||||||
13  | Test the resistance of the ambient air temperature sensor. Refer to Sensor Resistance Table . Is the resistance near the value in the Sensor Resistance Table?  | --  | Go to Testing for Intermittent Conditions and Poor Connections .  | Go to Step 15  | ||||||||||||
14  | Test the resistance of the inside air temperature sensor. Refer to Sensor Resistance Table . Is the resistance near the value in the Sensor Resistance Table?  | --  | Go to Step 19  | Go to Step 17  | ||||||||||||
15  | Inspect for poor connections at the harness connector of the ambient air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | --  | Go to Step 24  | Go to Step 17  | ||||||||||||
16  | Inspect the aspirator tube for a air leak or obstruction. Did you find and correct the condition?  | --  | Go to Step 24  | --  | ||||||||||||
17  | Inspect for poor connections at the harness connector of the inside air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | --  | Go to Step 24  | Go to Step 20  | ||||||||||||
18  | Inspect for poor connections at the harness connector of the sunload sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | --  | Go to Step 24  | Go to Step 22  | ||||||||||||
19  | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | --  | Go to Step 24  | Go to Step 23  | ||||||||||||
20  | Replace the inside air temperature sensor. Refer to Inside Air Temperature Sensor Replacement . Did you complete the replacement?  | --  | Go to Step 24  | --  | ||||||||||||
21  | Replace the sunload sensor. Refer to Sun Load Sensor Replacement . Did you complete the replacement?  | --  | Go to Step 24  | --  | ||||||||||||
22  | Replace the ambient air temperature sensor. Refer to Ambient Air Temperature Sensor Replacement . Did you complete the replacement?  | --  | Go to Step 24  | --  | ||||||||||||
23  | Replace the HVAC control module. Refer to Control Module References . Did you complete the replacement?  | --  | Go to Step 24  | --  | ||||||||||||
24  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 2  | ||||||||||||