Removal Procedure
Perform the following steps in order to open the transmitter case:
- Insert
a dime between the 2 halves of the transmitter case at the slot provided 
 near the key ring (5) hole.
 
- Twist the dime in order to open the case (6,4).
 
- Remove the battery (2).
 
Installation Procedure
- Install
the battery (2) with the positive (+) side facing down.
 
Use one 3-volt CR2032 battery or the equivalent.
- Ensure the transmitter case seal is in the proper position.
 
- Align the 2 halves of the transmitter case (6,4).
 
- Snap the 2 halves of the transmitter case together.
 
Important: Normal battery life is approximately 2 years. Replace the batteries
when the range of the transmitter begins to decrease significantly to less
   than approximately 7 m (23 ft).
- Test the operation of the transmitter.
 
If the transmitter does not function properly, resynchronization
may be necessary. Refer to 
Transmitter Synchronization 
.