Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
| 
 Important: A short to ground will cause an open fuse(s). Before performing this diagnostic procedure,inspect the fuse(s) for an open.  | ||||
1  | Did you perform the remote keyless entry system check?  | --  | Go to Step 2  | |
2  | 
 Does the test light illuminate?  | --  | Go to Step 3  | Go to Step 7  | 
3  | 
 Connect the test light between terminal N and terminal E of the connector. Does the test light illuminate?  | --  | Go to Step 5  | Go to Step 4  | 
4  | Repair an open in CKT 250 between the remote control door lock receiver connector terminal N and G302. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?  | --  | --  | |
5  | 
 Does the test light illuminate?  | --  | Go to Step 8  | Go to Step 6  | 
6  | Repair an open in CKT 43 between the connector terminal J and the fuse block. Did you complete the repair?  | --  | --  | |
7  | Repair an open in CKT 1733 between the connector terminal E and the multi-function alarm module connector C2 terminal C. Did you complete the repair?  | --  | --  | |
8  | Replace the remote control door lock receiver. Refer to Receiver Replacement in Keyless Entry. Did you complete the repair?  | --  | --  | |