- Use a flat blade screwdriver
in order to  disconnect the rod and clip assembly (701) from the manual valve
  (406).
 
- Remove the case cover
bolts and the two number 40 Torx™ head bolts.
 
Notice: Pry on the corner of the case side cover near the locating dowel pins
(111), to prevent damage to the sealing surfaces.
- Remove the case cover (401) from the case. A rubber mallet may be required
 in order to loosen the case cover from the case.
 
- Set the case cover (401) aside on a clean work area with the case
 side of the cover facing upward.
 
Important: The 1-2 accumulator piston (421) and the pin (422) may have remained
 within the case cover (401).
- Remove the 1-2 accumulator piston (421) and the pin (422).
 
- Remove the 1-2 accumulator spring (419).
 
Notice: Do not damage the case flanges when removing the gaskets.
- Remove the center gasket (415) from between the case and the case cover. 
 
- Remove the case cover gasket (416) from the case.