Removal Procedure
- Disconnect the electrical connection from the sensor.
 
Important: The sensor is mounted on a service fitting.
Do not discharge the system.
- Remove the A/C refrigerant pressure sensor. Discard the O-ring seal.
 
Installation Procedure
- Install the new O-ring seal. Refer to 
O-Ring Replacement 
.
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the A/C refrigerant pressure sensor.
 
Tighten
Tighten the sensor to 5 N·m (44 lb in).
- Connect the electrical connection to the sensor.