Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the SIR Diagnostic System Check?  | --  | Go to Step 2  | |
2  | 
 Is the voltage less than the specified value?  | 4-5 volts  | Go to Step 4  | Go to Step 3  | 
3  | Is the voltage greater than the specified value?  | 4-5 volts  | Go to Step 6  | |
4  | 
 Is continuity present?  | --  | Go to Step 5  | Go to Step 8  | 
5  | Locate and repair the short to ground in CKT 800 (TAN) between the Sensing and Diagnostic Module (SDM) and the DLC. Refer to SIR/SRS Wiring Repairs Is the repair complete?  | --  | --  | |
6  | 
 Is the voltage greater than the specified value?  | 0 volts  | Go to Step 8  | Go to Step 7  | 
7  | Locate and repair the short to voltage in CKT 800 (TAN) between the Sensing and Diagnostic Module (SDM) and the DLC. Refer to SIR/SRS Wiring Repairs Is the repair complete?  | --  | --  | |
8  | Perform the SDM Intergrity Check. Refer to Sensing and Diagnostic Module Integrity Check Did the SDM pass the check?  | --  | Go to Step 9  | |
9  | Replace the SDM. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement Is the repair complete?  | --  | --  |