Step 
 | Action 
 | Value(s) 
 | Yes 
 | No 
 | 
Definition: This diagnostic should only be used when one
power window (other then LF) doesn't work from either the master power window
  switch or  the individual power window switch. 
 | 
1 
 | Has the Power Windows System Check been performed? 
 | -- 
 | Go to 
Step 2
  
          
 | Go to 
Power Windows System Check  
 | 
2 
 | 
- Place the ignition switch in the RUN position.
 
- Connect a test lamp between CKT 1307 (DK BLU) and ground
at the appropriate power window switch.
 
 
Does the test lamp light? 
 | -- 
 | Go to 
Step 3
             
 | Go to 
Step 10
              
 | 
3 
 | 
- Connect a J 35616-200 
test lamp at the appropriate power window switch between the DK BLU
and BRN wires.
 
- Press UP the power window switch. Observe the test lamp.
 
- Press DOWN the power window switch. Observe the test lamp.
 
 
Does the test lamp light in both window switch position? 
 | -- 
 | Go to 
Step 4
            
 | Go to 
Step 5
            
 | 
4 
 | 
- Check for open(s) in the DK BLU and BRN wires between the power
window switch and the power window motor. Refer to 
Wiring Repairs 
   in Wiring Systems.
 
- If no open(s) are found, replace the power window motor. Refer
to 
Power Accessory Switch Panel Replacement 
  or 
Rear Side Door Window Switch Replacement 
  .
 
 
Is the repair complete? 
 | -- 
 | Go to 
Power Windows System Check  
 | -- 
 | 
5 
 | Connect a J 39200 
(DMM)
between ground and the appropriate power window switch  circuits: 
|     •  | RF, CKT 167 (TAN) and CKT 166 (LT BLU) |  
  
|     •  | RR, CKT 170 (LT GRN) and CKT 171 (PPL) |  
  
|     •  | LR, CKT 169 (PPL) and CKT 168 (LT GRN) |  
  
Is there continuity? 
 | -- 
 | Go to 
Step 6
             
 | Go to 
Step 7
              
 | 
6 
 | Replace
appropriate power window switch. Refer to 
Power Accessory Switch Panel Replacement 
 or 
Rear Side Door Window Switch Replacement 
  . 
Is the repair complete? 
 | -- 
 | Go to 
Power Windows System Check  
 | -- 
 | 
7 
 | Connect a J 39200 
(DMM)
between LF power window master switch connector C2  cavity C and ground. 
Is there continuity? 
 | -- 
 | Go to 
Step 9
                   
 | Go to 
Step 8
             
 | 
8 
 | Repair open in CKT 150 (BLK) between LF power window master switch
and G202. Refer to 
Wiring Repairs 
 
in Wiring  Systems. 
Is the repair complete? 
 | -- 
 | Go to 
Power Windows System Check  
 | -- 
 | 
9 
 | 
- Check for opens between the power window master switch and the
appropriate power window switch circuits:
 
| •  | RF, CKT 167 (TAN) and CKT 166 (LT
BLU). |  
  
| •  | RR, CKT 170 (LT GRN) and CKT 171 (PPL). |  
  
| •  | LR, CKT 169 (PPL) andCKT 168 (LT GRN). |  
  
- Repair circuits as necessary. Refer to 
Wiring Repairs 
  in Wiring Systems.
 
- If no opens are found, replace power window master switch. Refer
to 
Power Accessory Switch Panel Replacement 
.
 
 
Is the repair complete? 
 | -- 
 | Go to 
Power Windows System Check  
 | -- 
 | 
10 
 | Repair open in CKT 1307 (DK BLU) between appropriate the power
window switch and the window lockout switch. Refer to 
Wiring Repairs 
  in Wiring Systems. 
Is the repair complete? 
 | -- 
 | Go to 
Power Windows System Check  
 | -- 
 |