A/C  Pressure Sensor: The scan tool displays  0-3450
kPa (0-500 psi). The  voltage applied to the PCM input from the A/C
refrigerant pressure sensor   is converted to a pressure value.
A/C Pressure Sensor: The scan tool displays 0-5
volts. The voltage applied to  the PCM input for the A/C refrigerant pressure
sensor.
A/C Switch: The scan tool displays On/Off. The scan
tool displays On when the  A/C request switch is active. The scan tool displays
Off when the A/C request   switch is inactive.
A/C Relay Command: The scan tool displays On/Off. The
scan tool displays the control  decision for the compressor clutch relay output
as determined by the PCM.
A/C Request Signal: The scan tool displays Yes/No. The
scan tool displays Yes when  the PCM receives a class 2 message from
the HVAC control module to   engage the A/C compressor clutch. The scan tool
displays No when the PCM  receives  a class 2 message from the HVAC
control module to disengage  the A/C  compressor clutch.
Air Mix Door Left Commanded: The scan tool displays
0-255 counts. The scan tool displays  the desired left air temperature
door position as determined by the HVAC control   module.
Air Mix Door Right Commanded: The scan tool displays
0-255 counts. The scan tool displays  the desired right air temperature
door position as determined by the HVAC  control  module.
Battery Voltage: The scan tool displays 0-25 volts.
The voltage measured from  the battery positive voltage circuit and the ground
circuit of the HVAC control   module.
ECT Sensor: The scan tool displays -39 to 140°C
(-38 to 284°F) . The  voltage applied to the PCM input from the engine
coolant temperature sensor   is converted to a temperature value.
ECT Sensor: The scan tool displays 0-5 volts.
The voltage applied to  the PCM input for the engine coolant temperature sensor.
Ign. Since Current DTC: The scan tool displays 0-100.
The number of the ignition  cycles since the setting of the most recent current
diagnostic trouble code   (DTC).
Left Mix Door Actual: The scan tool displays 0-255
counts. The voltage applied  to the left air temperature door position input
of the HVAC control module   is converted to a number between 0 and 255 where
51 Counts is approximately   equal to 1 V.
Left Mix Motor Drive: The scan tool displays Stop, Increase,
or Decrease. The scan tool  displays the control decision for the actuator
output as determined by the   HVAC control module.
Left Temp. Detent Pos.: The scan tool displays 0 to
18. The scan  tool displays the position of the left air temperature switch.
Mode Door Actual: The scan tool displays 0-255
Counts. The voltage applied  to the HVAC control module input for the mode
door position is converted to   a number between 0 and 255 where 51 Counts
is approximately equal  to  1 V. 
Mode Door Commanded: The scan tool displays 0-255
counts. The scan tool displays  the desired mode door position as determined
by the HVAC control module.
Mode Motor Drive: The scan tool displays Stop, Increase,
or Decrease. The scan tool  displays the control decision for the actuator
output as determined by the   HVAC control module.
Mode Select Position: The scan tool displays Off, Defrost,
Heater, Htr/Def, Bi-Level,  Panel. The scan tool displays the state of mode
operation.
Pressure Cycle Switch: The scan tool displays Low Pressure/Normal.
The current state of  the input from the A/C low pressure switch. The scan
tool displays Low Pressure   when the switch is open and displays Normal when
the switch is closed. The   low pressure switch opens when low side pressure
decreases to approximately   151 kPa (22 psi) and closes when the low
side pressure increases to   approximately 275 kPa (40 psi).
Recirculate Switch: The scan tool displays
On/Off. The scan tool displays On when the  recirculation switch is active.
The scan tool displays Off when the recirculation   switch is inactive.
Right Mix Door Actual: The scan tool displays 0-255
counts. The voltage applied  to the right air temperature door position input
of the HVAC control  module  is converted to a number between 0 and 255 where
51 Counts  is approximately  equal to 1 V.
Right Motor Drive: The scan tool displays Stop, Increase,
or Decrease. The scan tool  displays the control decision for the actuator
output as determined by the   HVAC control module.
Right Temp. Detent Pos.: The scan tool displays 0 to
18. The scan  tool displays the position of the right air temperature switch.