Tools Required
|     •  | J 43764  Torque Converter End Play Gauge | 
 
|     •  | J 5959  Dial Indicator Clamp and Adjuster | 
 
|     •  | J 7872  Magnetic Base Dial Indicator | 
 
- Position the torque converter (3) on the work table so that the pump hub is facing up.
 
- Install 
J 43764   (2) into the torque converter hub.
 
- Hold 
J 43764   (2) in the converter hub and rotate the center screw until 
J 43764  is locked into the converter hub. Do not over tighten 
J 43764  
.
 
- Assemble the following tools and install the tools onto the torque converter as shown:
 
- Adjust the clamp (6) so that the dial indicator (1) firmly contacts the top of 
J 43764   (2). 
 
- Set the 
J 5959   (1) to read zero. 
 
- Lift 
J 43764   (2) upward as far as possible.
 
- Read the 
J 5959   (1) to determine torque converter end play. 
 
- Compare the measured end play with the torque converter end play specifications. Refer to 
End Play Specifications .
 
- If the measured torque converter end play exceeds the value listed, replace the torque converter.
 
- Remove the J tools from the converter housing.