Generator Assembly Bench Check CS-130
                    This test requires both a fully charged battery and a generator
test stand to operate the generator.
- Make connections as shown,
except leave the carbon pile turned off.  The ground polarity of the generator
and battery must be the same. The battery    must be fully charged. Use a
30-500 ohm resistor between the    battery and the L terminal.
 
- Slowly increase the generator speed and observe the voltage.
 
- If the voltage is uncontrolled and increases above 16 volts,
the rotor field is shorted, the regulator is not working properly, or both.
   A shorted rotor field coil can cause repeat regulator failure.
 
- If the voltage is below 16 volts, increase speed and turn
on and adjust the carbon pile to obtain maximum amperage output. Maintain
   the voltage above 13 volts.
 
- If the output is with 15 amperes of the rated output, the
generator is good.
 
- If the output is not within 15 amperes of the rated output,
replace the generator.