Step
| Action
| Value(s)
| Yes
| No
|
DEFINITION:
This diagnostic table should only be used if the LH mirror moves up and down
but will not move left to right.
|
1
|
- Disconnect the right power outside mirror connector.
- Position the selector switch to the RH power mirror.
- Connect a test lamp between CKT 881 (RED/WHT) cavity E and ground.
- Press the switch to the right position.
Does the test lamp light?
| --
| Go to
Step 2
| Go to
Step 3
|
2
| Replace the horizontal power mirror motor. Refer to
Outside Rearview Mirror Replacement
in Doors.
Is the repair complete?
| --
| System OK
| --
|
3
|
- Locate and repair open in CKT 881 (RED/WHT) between the RH outside
power mirror and the power mirror switch.
- If there is no open, replace the power mirror switch. Refer to
Power Accessory Switch Panel Replacement
.
Is the repair complete?
| --
| System OK
| --
|