Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the Horns Diagnostic System Check?  | --  | Go to Step 2  | |
2  | Verify the fault is present. Does the system operate normally?  | --  | Go to Testing for Intermittent Conditions and Poor Connections  | Go to Step 3  | 
3  | Remove the horn relay from the engine wiring harness junction block. Does the horn stop sounding?  | --  | Go to Step 4  | Go to Step 6  | 
4  | Connect a test lamp from the control circuit to fused battery positive voltage. Does the test lamp illuminate?  | --  | Go to Step 5  | Go to Step 8  | 
5  | 
 Does the test lamp illuminate?  | --  | Go to Step 7  | Go to Step 9  | 
6  | Repair the short to fused battery positive voltage in the horn relay output circuit between the engine wiring harness junction block and the left horn or the right horn (w/ RPO V22). Did you complete the repair?  | --  | Go to Step 10  | --  | 
7  | Repair a short to ground in the horn relay control circuit between the horn switch and the horn relay or in the horn brush/slip ring. Did you complete the repair?  | --  | Go to Step 10  | --  | 
8  | Replace the horn relay. Did you complete the repair?  | --  | Go to Step 10  | --  | 
9  | Replace the horn switch. Did you complete the repair?  | --  | Go to Step 10  | --  | 
10  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 3  |