Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the Diagnostic System Check?  | --  | Go to Step 2  | |
2  | Verify the fault is present. Does the system operate normally?  | --  | Go to Testing for Intermittent Conditions and Poor Connections  | Go to Step 3  | 
3  | 
 Does the test lamp illuminate?  | --  | Go to Step 4  | Go to Step 10  | 
4  | Use a Digital Multi Meter (DMM) to test the ground circuit of the left power window switch for continuity. Is there continuity?  | --  | Go to Step 5  | Go to Step 9  | 
5  | 
 Does the test lamp illuminate?  | --  | Go to Step 6  | Go to Step 7  | 
6  | Test the power window motor feed-LF up and power window motor feed-LF down circuits for an open or short to ground. Did you find and correct the condition?  | --  | Go to Step 11  | Go to Step 8  | 
7  | Replace the left power window/door lock switch. Refer to Front Side Door Window Switch Replacement . Is the repair complete?  | --  | Go to Step 11  | --  | 
8  | Replace the left power window motor. Refer to Front Side Door Window Module Replacement . Is the repair complete?  | --  | Go to Step 11  | --  | 
9  | Locate and repair a loose connection or an open in the left power window switch ground circuit. Refer to Circuit Testing and Wiring Repairs Is the repair complete?  | --  | Go to Step 11  | --  | 
10  | Locate and repair a loose connection or an open in the fused RAP relay output circuit. Refer to Circuit Testing and Wiring Repairs . Is the repair complete?  | --  | Go to Step 11  | --  | 
11  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 3  |