Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you review the Power Door Lock Operation and perform the necessary inspections?  | --  | ||
2  | Verify the fault is present. Does the system operate normally?  | --  | Go to Testing for Intermittent Conditions and Poor Connections  | |
3  | 
 Does the scan tool show any DTCs?  | --  | Go to Diagnostic System Check - Body Control System in Body Controls  | |
4  | Connect a test lamp (back probe) from the fused battery feed at the inoperative switch to ground. Does the test lamp illuminate?  | --  | ||
5  | Locate and repair the open in fused battery feed between the fuse and the switch. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?  | --  | --  | |
6  | Depress the inoperative switch to the unlock position. Do the doors unlock?  | |||
7  | 
 Does the test lamp illuminate?  | --  | ||
8  | Locate and repair the open in the power door unlock relay feed between switch and the BCM. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?  | --  | --  | |
9  | Replace the inoperative switch. Did you complete the repair?  | --  | --  | |
10  | 
 Does the test lamp illuminate?  | --  | ||
11  | Locate and repair the open in power door lock relay feed between the switch and the lock relay. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?  | --  | --  | |
12  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  |