Step  | Action  | Yes  | No  | ||||||
|---|---|---|---|---|---|---|---|---|---|
1  | Were you sent here from Symptoms or another diagnostic table?  | Go to Step 2  | |||||||
2  | Is one of the following a concern of the customer: 
 
 
 Does the mode control operate too freely?  | Go to Step 3  | Go to Step 7  | ||||||
3  | With the ignition in the ON position: 
 Does the air outlet change through all of the modes?  | Go to Step 16  | Go to Step 4  | ||||||
4  | Inspect the connections of the mode control cable. Is the mode control cable disconnected from the mode actuator?  | Go to Step 15  | Go to Step 5  | ||||||
5  | Inspect the mode control cable and linkage, while operating the mode controls. Does the mode actuator move while operating the mode controls?  | Go to Step 21  | Go to Step 6  | ||||||
6  | Inspect the cable casing while operating the mode controls. Does the cable casing move, instead of the cable, while operating the mode controls?  | Go to Step 18  | Go to Step 21  | ||||||
7  | Inspect the HVAC control assembly for any debris or obstructions that would increase the effort to operate the mode controls. Are there any obstructions?  | Go to Step 20  | Go to Step 8  | ||||||
8  | 
 Does the HVAC control assembly bind now?  | Go to Step 10  | Go to Step 9  | ||||||
9  | With the mode control cable disconnected: 
 Does the mode actuator bind with the cable disconnected?  | Go to Step 19  | Go to Step 10  | ||||||
10  | 
 Does the HVAC control assembly bind now?  | Go to Step 16  | Go to Step 11  | ||||||
11  | With the mode control cable disconnected at both ends: 
 Does the mode control cable bind?  | Go to Step 17  | Go to Step 12  | ||||||
12  | 
 Does the mode cable still bind?  | Go to Step 17  | Go to Step 13  | ||||||
13  | Operate the HVAC control assembly with the mode control cable disconnected. Does the HVAC control assembly bind now?  | Go to Step 16  | Go to Step 14  | ||||||
14  | Reassemble the mode control system. Is the action complete?  | Go to Step 21  | --  | ||||||
15  | Reconnect the mode control cable to the mode actuator linkage install the cable retainers. Is the action complete?  | Go to Step 21  | --  | ||||||
16  | Replace the HVAC control module. Refer to HVAC Control Module Replacement . Is the repair complete?  | Go to Step 21  | --  | ||||||
17  | Replace the mode control cable. Refer to Mode Control Cable Replacement . Is the repair complete?  | Go to Step 21  | --  | ||||||
18  | Secure the mode control cable casing. Is the action complete?  | Go to Step 21  | --  | ||||||
19  | Repair the binding door. Refer to the appropriate repair: Is the repair complete?  | Go to Step 21  | --  | ||||||
20  | Remove the debris. Is the action complete?  | Go to Step 21  | --  | ||||||
21  | Operate the system in order to verify the repair. Did you find and correct the condition?  | System OK  | Go to Step 2  |