| Table 1: | HVAC Control Module Scan Tool Data List | 
| Table 2: | PCM Scan Tool Data List | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)  | |||
A/C Switch  | Input/Output  | On, Off  | Off  | 
Mode Door Actual  | Door Positions  | Counts  | Varies  | 
Mode Door Commanded  | Door Positions  | Counts  | Varies  | 
Mode Motor Drive  | Door Positions  | Stop, Increase, Decrease  | Stop  | 
Air Inlet Motor Drive  | Door Positions  | Fresh Air, Recirc.  | Varies  | 
Air Mix Door Left Commanded  | Door Positions  | Counts  | Varies  | 
Air Mix Door Right Commanded  | Door Positions  | Counts  | Varies  | 
Battery Voltage  | Input/Output  | Volts  | 13.5-14.5 V  | 
Blower Motor Status  | Input/Output  | Active, Inactive  | Active  | 
Ign. Since Current DTC  | Input/Output  | Numeric  | 0  | 
Left Mix Door Actual  | Door Positions  | Counts  | Varies  | 
Left Mix Motor Drive  | Door Positions  | Stop, Increase, Decrease  | Stop  | 
Left Temp. Detent Pos.  | Input/Output  | 0-18  | Varies  | 
Mode Select Position  | Door Positions  | Off, Auto, Defrost, Heater, Htr/Def, Bi-level, Panel  | Varies  | 
Pressure Cycle Switch  | Input/Output  | Low Pressure, Normal  | Varies  | 
Recirculate Switch  | Input/Output  | On, Off  | Off  | 
Right Mix Door Actual  | Door Positions  | Counts  | Varies  | 
Right Mix Motor Drive  | Door Positions  | Stop, Increase, Decrease  | Stop  | 
Right Temp Detent Pos.  | Input/Output  | 0-18  | Varies  | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)  | |||
A/C Pressure Sensor  | Engine Data 2  | kPa, Psi  | 629-845 kPa (85-120 psi)  | 
A/C Pressure Sensor  | Engine Data 2  | Volts  | Varies  | 
A/C Relay Command  | Engine Data 2  | On, Off  | Varies  | 
A/C Request Signal  | Engine Data 2  | Yes, No  | Varies  | 
ECT Sensor  | Engine Data 2  | °C/°F  | 92°C (197°F)  | 
ECT Sensor  | Engine Data 2  | Volts  | 1.10-1.45 Volts  |