Step  | Action  | Yes  | No  | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Exterior Lights Schematics Connector End View Reference: Lighting Systems Connector End Views  | |||||||||||
1  | Did you perform the Lighting Systems Diagnostic System Check?  | Go to Step 2  | |||||||||
2  | Verify that the roof beacon lamp is inoperative. Does the roof beacon lamp operate normally?  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | Go to Step 3  | ||||||||
3  | 
 Does the test lamp illuminate?  | Go to Step 8  | Go to Step 4  | ||||||||
4  | Test the ground circuit of the roof beacon lamp for a high resistance or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition?  | Go to Step 11  | Go to Step 5  | ||||||||
5  | 
 Does the roof beacon lamp illuminate?  | Go to Step 9  | Go to Step 6  | ||||||||
6  | Test the following circuits for a high resistance, open or a short to ground: 
 
 
 
 Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition?  | Go to Step 11  | Go to Step 7  | ||||||||
7  | Test the ground circuit of the roof beacon relay for a high resistance or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition?  | Go to Step 11  | Go to Step 10  | ||||||||
8  | Replace the bulb or lamp assembly. Refer to upfitter instructions. Did you complete the replacement?  | Go to Step 11  | --  | ||||||||
9  | Replace the roof beacon switch. Did you complete the replacement?  | Go to Step 11  | --  | ||||||||
10  | Replace the roof beacon relay. Refer to Relay Replacement in Wiring Systems. Did you complete the replacement?  | Go to Step 11  | --  | ||||||||
11  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 3  | ||||||||