Removal Procedure
- Using a bent-tip screwdriver or equivalent, pull
on one of the open ends of the retaining ring in order to rotate the retaining ring.
 
- Rotate the retaining ring around the quick connector until the retaining ring is out of position and can be completely removed.
 
- Remove the generator control module (GCM) radiator hose from the GCM radiator.
 
Installation Procedure
Important: Do not install the retaining ring onto the fitting by pushing the retaining ring down over the fitting.
- Hook one of the open ends of the retaining ring in one of the slots in the quick connector.
 
- Rotate the retaining ring around the connector until
the retaining ring is positioned with all 3 ears through the 3 slots.
 
- Ensure the 3 retaining ring ears can be seen from the inside of the connector and the retaining ring can move freely in the slots.
 
- Install the GCM radiator hose to the GCM radiator quick connector fitting until a click is heard or felt.
 
Pull back on the GCM radiator hose to ensure a proper connection.