Range  | Pressure Switch C - N/O  | Pressure Switch D - N/O  | Pressure Switch E - N/O  | Pressure Switch R - N/C  | ||||
|---|---|---|---|---|---|---|---|---|
Switch Status  | Scan Tool Status  | Switch Status  | Scan Tool Status  | Switch Status  | Scan Tool Status  | Switch Status  | Scan Tool Status  | |
R  | Open  | OFF*  | Closed  | ON  | Closed  | ON  | Closed  | ON  | 
N  | Closed  | ON  | Closed  | ON  | Closed  | ON  | Open  | OFF  | 
1  | Open  | OFF  | Closed  | ON  | Open  | OFF  | Open  | OFF  | 
2  | Open  | OFF  | Open  | OFF  | Open  | OFF  | Open  | OFF  | 
3  | Closed  | ON  | Open  | OFF  | Open  | OFF  | Open  | OFF  | 
4  | Closed  | ON  | Open  | OFF  | Closed  | ON  | Open  | OFF  | 
5  | Open  | OFF**  | Open  | OFF  | Closed  | ON  | Open  | OFF  | 
N/C = Normally Closed N/O = Normally Open * C pressure switch reverts to the Closed/ON state with throttle applied in Reverse. ** MY 2001 only; in 5th range, C pressure switch remains in the Closed/ON state until 3,900 RPM is attained.  | ||||||||