| Table 1: | Instrument Panel Cluster (IPC) | 
| Table 2: | Powertrain Control Module (PCM) | 
| Table 3: | Hybrid Control Module (HCM) | 
| Table 4: | Starter Generator Control Module (SGCM) | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Ignition Switch in RUN/Engine running/Automatic Transmission in PARK/Manual Transmission in NEUTRAL/Air Conditioner is OFF  | |||
Displayed Coolant Temp  | Data  | Celsius (C)/Fahrenheit (F)  | 87°C (189°F)  | 
Monitored Coolant Temp  | Data  | Celsius (C)/Fahrenheit (F)  | 87°C (Fluctuates range 82-93°C) 189°F (Fluctuates range 180-200°F)  | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Ignition Switch in RUN/Engine running/Automatic Transmission in PARK/Manual Transmission in NEUTRAL/Air Conditioner is OFF  | |||
Coolant Level Switch  | Engine Data 2  | Low/OK  | OK  | 
ECT Sensor  | Engine Data 1 Engine Data 2  | Degrees  | 87°C (189°F)  | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Ignition Switch in RUN/Engine running/Automatic Transmission in PARK/Manual Transmission in NEUTRAL/Air Conditioner is OFF  | |||
Aux. Coolant Pump Relay  | HPCM Data  | On/Off  | Off  | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Ignition Switch in RUN/Engine running/Automatic Transmission in PARK/Manual Transmission in NEUTRAL/Air Conditioner is OFF  | |||
SGCM Temperature  | SGCM Data  | Celsius (C)/Fahrenheit (F)  | Varies  | 
SGCM Fan Speed  | SGCM Data  | 0-100%  | 0%  | 
SGCM Pump Status  | SGCM Data  | On/Off  | Off  |