Cause  | Action  | ||||||||
|---|---|---|---|---|---|---|---|---|---|
The column mounting bracket bolts are loose.  | Tighten the connection. Refer to Fastener Tightening Specifications .  | ||||||||
The weld nut on the jacket is broken.  | Replace the jacket assembly. Refer to the appropriate procedure from the following list: 
 
 
 
  | ||||||||
The column bracket capsule is sheared.  | Replace the jacket assembly. Refer to the appropriate procedure from the following list: 
 
 
 
  | ||||||||
The tilt head pivot pins are loose.  | Replace the jacket assembly. Refer to the appropriate procedure from the following list: 
 
 
 
  | ||||||||
The shoe lock pin in the support is loose.  | Replace the jacket assembly. Refer to the appropriate procedure from the following list: 
 
 
 
  | ||||||||
The support screws are loose.  | Tighten the support screws. Refer to Fastener Tightening Specifications .  | ||||||||
The upper and the lower bracket to jacket bolts are loose.  | Tighten the bolts to the specified torque. Refer to Fastener Tightening Specifications .  | ||||||||
The lower bracket to adapter and bearing assembly mounting bolts are loose.  | Tighten the mounting screws to the specified torque. Refer to Fastener Tightening Specifications .  | ||||||||
The instrument panel to jacket mounting bolts are loose.  | Tighten the mounting bolts to the specified torque. Refer to Fastener Tightening Specifications .  |