Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the OBD II System Check been performed?  | --  | Go to Step 2  | Go to Powertrain On Board Diagnostic (OBD) System Check (5.0L/5.7L); Powertrain On Board Diagnostic (OBD) System Check (7.4L)  | 
2  | 
 Is continuity present?  | --  | Go to Step 3  | Go to Step 4  | 
3  | Locate and repair the short to ground in CKT 121 (WHT) between the Ignition Coil and the I/P cluster. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | --  | |
4  | Connect a J 39200 DMM (continuity) from I/P Cluster cavity 6 to ignition coil connector cavity B. Is continuity present?  | --  | Go to Step 5  | Go to Step 6  | 
5  | Replace the I/P Cluster. Refer to Instrument Cluster Replacement . Is the repair complete?  | --  | --  | |
6  | Locate and repair the open in CKT 121 (WHT) between the Ignition Coil and the I/P Cluster. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | --  | 
Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the Instrument Cluster System Check?  | --  | Go to Step 2  | |
2  | 
 Did the test lamp light?  | --  | Go to Step 3  | Go to Step 4  | 
3  | Locate and repair the short to ground in CKT 121 (WHT) between the generator and the instrument cluster. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | Go to Step 4  | |
4  | Connect a J 35616-200 test lamp between instrument cluster connector cavity 6 and generator connector cavity A. Did the test lamp light?  | --  | Go to Step 5  | Go to Step 6  | 
5  | 
 Is there voltage present?  | 14 V  | Go to Step 7  | Go to Step 8  | 
6  | Locate and repair the open in CKT 121 (WHT) between the generator and the instrument cluster. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | --  | |
7  | Replace the instrument cluster. Refer to Instrument Cluster Replacement . Is the repair complete?  | --  | --  | |
8  | Replace the generator. Refer to Generator Replacement or Auxiliary Generator Replacement in Engine Electrical. Is the repair complete?  | --  | --  |