Step 
 | Action 
 | Value(s) 
 | Yes 
 | No 
 | 
1 
 | Has the Power Door Locks System
Check been performed? 
 | -- 
 | Go to 
Step 2
       
 | Go to 
Power Door Locks System Check  
 | 
2 
 | 
- Disconnect the inoperative power door lock switch.
 
- Connect a J 35616-200 
 test lamp from CKT 640 (ORN) to the power door lock switch
and ground.
 
 
Does the test lamp light? 
 | -- 
 | Go to 
Step 3
       
 | Go to 
Step 4
        
 | 
3 
 | 
- Connect a fused jumper from the inoperative power door lock switch,
CKT 640 (ORN) to CKT 194 (LT BLU).
 
- Connect the fused jumper from the inoperative power door lock
switch, CKT 640 (ORN) TO CKT 194 (WHT).
 
 
Do the doors lock and then unlock? 
 | -- 
 | Go to 
Step 5
          
 | Go to 
Step 6
           
 | 
4 
 | Repair the open in CKT 640 (ORN) between the inoperative power
door lock switch and splice S256. Refer to 
Wiring Repairs 
  in Wiring Systems. 
Is the repair complete? 
 | -- 
 | Go to 
Power Door Locks System Check  
 | -- 
 | 
5 
 | Replace the door lock switch. Refer to 
Power Accessory Switch Panel Replacement 
. 
Is the repair complete? 
 | -- 
 | Go to 
Power Door Locks System Check  
 | -- 
 | 
6 
 | 
- Inspect CKT 194 (WHT) and CKT 195 (LT BLU) for opens.
 
- Repair the circuits, as necessary. Refer to 
Wiring Repairs 
 in Wiring Systems.
 
 
Is the repair complete? 
 | -- 
 | Go to 
Power Door Locks System Check  
 | -- 
 |