Step 
 | Action 
 | Value(s) 
 | Yes 
 | No 
 | 
DEFINITION : This diagnostic should be
used only when the window is operative from the  master power window switch
and inoperative from  the individual  power window  switch. 
 | 
1 
 | Has the
Power Window System Check been performed? 
 | -- 
 | Go to 
Step 2
   
 | Go to 
Power Windows System Check  
 | 
2 
 | 
- Place the ignition switch in the RUN position.
 
- Place the window lockout switch in the normal position.
 
- Connect a J 35616-200 
 test lamp between CKT 1307 (DK BLU) and ground at the
appropriate power window switch connector.
 
 
Does the test lamp light? 
 | -- 
 | Go to 
Step 3
   
 | Go to 
Step 4
  
 | 
3 
 | 
- Inspect the appropriate power window switch connector for a faulty
connection.
 
- If the connection is OK, replace the appropriate power window
switch. Refer to 
Power Accessory Switch Panel Replacement 
,
Rear Side Door Window Switch Replacement 
.
 
 
Is the repair complete? 
 | -- 
 | Go to 
Power Windows System Check  
 | -- 
 | 
4 
 | Repair the open in CKT 1307 (DK BLU) between the appropriate
power window switch connector and the window lockout switch. Refer to 
Wiring Repairs 
. 
Is the repair complete? 
 | -- 
 | Go to 
Power Windows System Check  
 | -- 
 |