- Install a NEW exhaust manifold pipe seal to the exhaust manifold pipe.
 
- Install the exhaust manifold pipe.
 
- Using the transmission jack, raise the transmission.
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the exhaust manifold pipe nuts. 
 
Tighten
Tighten the nuts to 50 N·m (39 lb ft).
- If the old oxygen sensor is being reused, apply anti-seize compound GM P/N 12377953
or equivalent to the threads.
 
- Install the oxygen sensor.
 
Tighten
Tighten the sensor to 42 N·m (31 lb ft).
- Connect the oxygen sensor electrical connector.
 
- Connect the CPA retainer.
 
- Install the clip around the engine harness and the oxygen sensor pigtail.
 
- Install the exhaust pipe/catalytic converter to the vehicle.
 
- Install the exhaust system hangers.
 
- Depending on which side is being replaced, perform one of the following steps:
 
| •  | Install the exhaust muffler nuts. | 
 
Tighten
Tighten the nuts to 40 N·m (30 lb ft).
| •  | Install a NEW exhaust pipe clamp. | 
 
Tighten
Tighten the clamp to 44 N·m (33 lb ft).
- Install the transmission support crossmember.
 
- Install the transmission support crossmember bolts.
 
Tighten
Tighten the bolts to 95 N·m (70 lb ft).
- Lower the transmission onto the transmission support.
 
- Install the transmission mount to transmission support nuts.
 
Tighten
Tighten the nuts to 40 N·m (30 lb ft).
- Remove the transmission jack.
 
- Lower the vehicle.