| Table 1: | ECC Scan Tool Output Controls | 
| Table 2: | PCM Scan Tool Output Controls | 
Scan Tool Output Control  | Additional Menu Selection(s)  | Description  | 
|---|---|---|
Rear defogger  | Miscellaneous  | The scan tool displays Commanded State: None, Off or On. The selection activates or deactivates the rear defrost.  | 
A/C Request  | Miscellaneous  | The scan tool displays Commanded State: None, Off or On. The selection activates or deactivates the A/C request signal.  | 
Recirculation Mode  | Miscellaneous  | The scan tool displays Commanded State: None, Off or On. The selection activates or deactivates the recirc light and drives the recirculation door to the recirculation position.  | 
Outside Air Mode  | Miscellaneous  | The scan tool displays Commanded State: None, Off or On. The selection activates or deactivates the recirc light and drives the recirculation door to the outside air position.  | 
Air Inlet Door  | Motor/Actuator tests  | The scan tool displays Outside or Recirc selections. The selection drives the actuator to its min or max stops.  | 
Blower Motor  | Motor/Actuator tests  | The scan tool displays Commanded State: None, Off or On. This function allows you to command the blower motor to its maximum (100%) or minimum (0%) speeds.  | 
Blower Motor Auxiliary  | Motor/Actuator tests  | The scan tool displays Commanded State: None, Off or On. This function allows you to command the auxiliary blower motor to its maximum (100%) or minimum (0%) speeds.  | 
Mode Door Position  | Motor/Actuator tests  | The scan tool displays Defrost or Panel selections. The selection drives the actuator to its min or max stops.  | 
Auxiliary Mode Door  | Motor/Actuator tests  | The scan tool displays Upper Outlets or Floor selections. The selection drives the actuator to its min or max stops.  | 
Instant OAT Update  | Miscellaneous  | The scan tool displays Commanded State: None, Off or On. Updates the ECC outside air temperature input to the current raw value.  | 
Mix Motor  | Motor/Actuator tests  | The scan tool displays Commanded State: None, Off or On. The selection drives the temperature actuator to its min or max stops.  | 
Auxiliary Mix door  | Motor/Actuator tests  | The scan tool displays Commanded State: None, Off or On. The selection drives the auxiliary temperature actuator to its min or max stops.  | 
Set up new HVAC  | Set up new HVAC  | This function allows the control module to learn what auxiliary system the vehicle is equipt with.  | 
Scan Tool Output Control  | Additional Menu Selection(s)  | Description  | 
|---|---|---|
A/C Relay  | --  | The scan tool displays On or Off selections. This command allows you to turn the A/C relay ON or OFF.  |