Special Tools
|     •  | GE-48494 
 Power Electronics Pressure Test Adapter Kit | 
 
Removal Procedure
- Remove the drive motor generator control
module from the vehicle. Refer to 
Drive Motor Generator Control Module Assembly Replacement.
 
- Remove the APM ground strap bolt (1) and ground strap (2).
 
- Remove the temporary coolant pipe caps (1).
 
Caution: The module must be drained of all residual coolant prior to disassembly. Failure to properly drain all residual coolant may cause electronic circuit damage to occur during disassembly.
Important: Place a container under the coolant outlet pipe to capture the escaping coolant.
- Drain the drive motor generator control module assembly of residual coolant by applying 30 psi regulated compressed air to the coolant inlet pipe until no coolant remains.
 
- Remove the drive motor generator power inverter control
module (PIM) electronics cover fasteners (1).
 
- Remove the PIM electronics cover (2). Discard the cover seal (3).
 
Caution: Always remove and install the High Voltage terminal fasteners with a magnet tipped socket. Never touch the exposed electronic circuit board surface or components. Dropped fasteners or physical
contact may result in electronic circuit board damage.
- Remove the HV dc accessory DC power control module (APM) terminal fasteners (1) utilizing a magnetic socket.
 
- Temporarily install the PIM electronics
cover (2) with 4 finger-tightened fasteners (1).
 
- Rotate the drive motor generator control
module assembly onto the PIM electronics cover.
 
- Remove the APM to PIM mounting fasteners (1).
 
- Remove the APM (2) and discard the coolant seal (3).
 
Installation Procedure
- Install new APM coolant seal (3).
 
- Position the APM (2) onto the PIM ensuring the seals remain in place.
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the APM mounting fasteners (1).
 
Tighten
Tighten the mounting fasteners to 10 N·m (89 lb in).
- Rotate the drive motor generator control
module assembly onto the APM.
 
- Clamp the 
GE-48494 
 components (2, 3) to a coolant pipe.
 
- Plug the remaining coolant pipe with the 
GE-48494 
 plug and clamp (1).
 
- Apply the specified pressure with 
J 24460-01 
  (4).
 
Pressure
Apply 20 psi (138 kPa) pressure.
- Monitor the pressure tester gauge for 5 minutes and ensure that pressure remains at the specified value.
 
| •  | If the specified pressure cannot be maintained, disassemble the drive motor generator control module assembly and replace the coolant seals. | 
 
| •  | If pressure remains at the specified value, proceed to the next step. | 
 
- Remove all 
GE-48494 
 components.
 
- Remove the PIM cover retaining bolts (1).
 
- Remove the PIM electronics cover (2).
 
Caution: Always remove and install the High Voltage terminal fasteners with a magnet tipped socket. Never touch the exposed electronic circuit board surface or components. Dropped fasteners or physical
contact may result in electronic circuit board damage.
- Install the HV dc APM terminal fasteners (1) utilizing a magnetic socket.
 
Tighten
Tighten the terminal fasteners to 9 N·m (80 lb in).
- Install a new PIM cover seal (3).
 
- Position the PIM cover (2) onto the PIM ensuring the seal remains in place.
 
- Install the PIM cover fasteners (1).
 
Tighten
Tighten the fasteners to 5 N·m (44 lb in).
- Install the ground strap (2)
and bolt (1).
 
Tighten
Tighten the bolt to 22 N·m (16 lb ft).