Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor is ON while the blower motor switch is in the OFF position.  | |||
1  | Did you perform the Diagnostic System Check - Vehicle?  | Go to Step 2  | |
2  | 
 Is the blower motor OFF?  | Go to Testing for Intermittent Conditions and Poor Connections  | Go to Step 3  | 
3  | 
 Is the blower motor OFF?  | Go to Step 4  | Go to Step 5  | 
4  | Test the Low, Med 1 and Med 2 blower motor control circuits for a short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 8  | Go to Step 6  | 
5  | Test the high blower motor control circuit for a short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 8  | Go to Step 6  | 
6  | Inspect for poor connections at the harness connector of the HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 8  | Go to Step 7  | 
7  | Replace the HVAC control assembly. Refer to Heater and Air Conditioning Control Replacement . Did you complete the replacement?  | Go to Step 8  | --  | 
8  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 2  |