Removal Procedure
- Remove the fuse labeled HVAC CTRL (BATT).
 
- Remove the instrument panel (I/P) retainer. Refer to 
Instrument Panel Tie Bar Replacement
 in Instrument Panel, Gages, and Console.
 
- Disconnect the recirculation actuator electrical connector.
 
- Remove the recirculation actuator screw.
 
- Remove the recirculation actuator.
 
Installation Procedure
Important: The key should be in the OFF position when connecting the electrical connectors to ensure proper calibration.
- Install the recirculation actuator.
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the recirculation actuator screw.
 
Tighten
Tighten the screw to 2.2 N·m (19 lb in).
- Install the recirculation electrical connector.
 
- Install the I/P retainer. Refer to 
Instrument Panel Tie Bar Replacement
 in Instrument Panel, Gages, and Console.
 
- Install the fuse labeled HVAC CTRL (BATT).
 
Important: Do not adjust any controls on the HVAC control assembly while the HVAC control assembly and actuators are calibrating. If interrupted improper HVAC performance will result.
- Start the engine and let run for one minute.