Caution: Refer to Test Probe Caution in the Preface section.
The following procedure measures the voltage at a selected point in a circuit.
- Disconnect the electrical harness connector for the circuit being tested, if necessary.
 
- Enable the circuit and/or system being tested. Use the following methods:
 
| •  | Turn ON the ignition, with the engine OFF. | 
 
| •  | Turn ON the circuit and/or system with a scan tool in Output Controls. | 
 
| •  | Turn ON the switch for the circuit and/or system being tested. | 
 
- Select the V (AC) or V (DC) position on the DMM.
 
- Connect the positive lead of the DMM to the point of the circuit to be tested. 
 
- Connect the negative lead of the DMM to a good ground. 
 
- The DMM displays the voltage measured at that point.