Step  | Action  | Value  | Yes  | No  | ||||||
|---|---|---|---|---|---|---|---|---|---|---|
DEFINITION: The high and low side pressures may be normal or slightly less than normal. 
 
 
  | ||||||||||
1  | Were you sent here from the A/C System Performance Test?  | --  | Go to Step 2  | |||||||
2  | Refer to the panel air outlet temperatures recorded during the A/C system performance test. Does the discharge air temperature between the right and left center panel outlets vary by more than 4°C (5°F)?  | --  | Go to Step 7  | Go to Step 3  | ||||||
3  | Did the customer mention that the A/C system output temperatures are good at first, but then turn warm during extended drives?  | --  | Go to Step 4  | Go to Step 5  | ||||||
4  | Increase engine speed to 2,000 RPM. During extended operation of the A/C system, does the low side pressure decrease, possibly accompanied by heavy frost on the liquid line between the expansion device and the evaporator?  | --  | Go to Step 5  | |||||||
5  | Refer to the pressures recorded during the A/C system performance test. Inspect for the following conditions: Warning: Refer to Moving Parts and Hot Surfaces Warning in the Preface section. 
 
 
 Do the listed conditions exist?  | --  | Go to Step 7  | Go to Step 6  | ||||||
6  | Refer to the pressures recorded during the A/C system performance test. Inspect for the following conditions: 
 
 
 Do the listed conditions exist?  | --  | Go to Step 8  | |||||||
7  | The A/C system may be undercharged. 
 Is the repair complete?  | --  | Go to Step 13  | --  | ||||||
8  | The A/C system may be contaminated. View the J 43600 ACR 2000 Air Conditioning Service Center information screen for detection of foreign gases in the A/C system. Do foreign gases exist?  | --  | Go to Step 9  | Go to Step 10  | ||||||
9  | 
 Is the repair complete?  | --  | Go to Step 13  | --  | ||||||
10  | The A/C system may contain too much moisture or air. 
 Are the panel outlet temperatures within the specified ranges of the A/C Performance Test Table?  | --  | Go to Step 14  | Go to Step 11  | ||||||
11  | 
 Note: Review the vehicles A/C repair history. If the vehicle history shows multiple A/C repairs and is suspected of improper polyalkylene glycol (PAG) oil balancing in the previous repairs, perform the following procedure: Was more than the total system capacity of refrigerant oil recovered from the J 43600 oil drain bottle?  | 148 ml (5 oz)  | Go to Step 12  | Go to Step 12  | ||||||
12  | 
 Are the actions complete?  | --  | Go to Step 13  | --  | ||||||
13  | 
 Are the high and low side pressures and I/P outlet temperatures within specifications?  | --  | Go to Step 14  | |||||||
14  | Operate the system in order to verify the repair. Did you find and correct the condition?  | --  | System OK  | |||||||