Special Tools
J 39400-A  Halogen Leak Detector
Removal Procedure
- Recover the refrigerant. Refer to 
Refrigerant Recovery and Recharging.
 
- Remove the condenser tube and evaporator hose from the thermal expansion valve (TXV).
 
- Remove and discard the seal washer.
 
- Remove the air conditioning evaporator thermal expansion valve screen.
 
Installation Procedure
- Install the air conditioning evaporator thermal expansion valve screen.
 
- Install new sealing washers on the condenser tube and evaporator hose fittings. Refer to 
Sealing Washer Replacement.
 
- Install the condenser tube and evaporator hose to the TXV.
 
Caution: Refer to Fastener Caution in the Preface section.
- Install the TXV nut.
 
Tighten
Tighten the nut to 20 N·m (15 lb ft).
- Evacuate and charge the refrigerant system. Refer to 
Refrigerant Recovery and Recharging.
 
- Leak test the fittings using the 
J 39400-A .