Blower Motor High Speed Inoperative (Position 5) <<C60>>
Step
| Action
| Value(s)
| Yes
| No
|
DEFINITION: Blower motor operates at all speeds except
high (position 5).
|
1
| Were you sent here
from the HVAC System Check (C60)?
| --
|
Go to Step 2
| Go to HVAC System Check (C60)
|
2
|
- Disconnect the blower motor control module connector C1.
- Connect a DMM between terminal F of the blower motor module connector
C1 and a known good ground.
- Turn the ignition switch to the ON position.
- Place the HVAC selector switch in the VENT position.
- Turn the blower switch to position 5.
- Measure the available voltage at terminal F of the blower motor
module connector C1.
Is the voltage within the specified values?
| 10.0 -14.0V
|
Go to Step 6
|
Go to Step 3
|
3
|
- Turn the ignition switch to the OFF position.
- Disconnect the HVAC control head connector C2.
- Connect a DMM between the HVAC control head connector C2 terminal
C and the blower motor module connector C1 terminal F.
- Measure CKT 52 for continuity between these connectors.
Is CKT 52 continuous between the HVAC control head connector C2 and
the blower motor module connector C1?
| --
|
Go to Step 4
|
Go to Step 5
|
4
| Replace
the HVAC control head.
Is the repair complete?
| --
| Go to HVAC System Check (C60)
| --
|
5
| Locate and repair an open or a
high resistance in CKT 52.
Is the repair complete?
| --
| Go to HVAC System Check (C60)
| --
|
6
|
- Connect a DMM between the blower motor control module connector
C1 terminal G and a known good ground.
- Measure the available voltage at terminal G of the blower motor
module connector C1
Is the voltage within the specified values?
| 10.0 -14.0V
|
Go to Step 8
|
Go to Step 7
|
7
| Locate and repair an open or a high resistance in CKT 1342
between the instrument panel electrical center and the blower motor control
module connector C1.
Is the repair complete?
| --
| Go to HVAC System Check (C60)
| --
|
8
| Replace the blower motor control
module.
Is the repair complete?
| --