Cigar lighter is inoperative
Step
| Action
| Value(s)
| Yes
| No
|
1
|
- Disconnect the cigar lighter connector.
- Connect a DMM between the cigar lighter connector terminal B and
ground.
- Measure for continuity to ground in CKT 150.
Is the resistance to ground less than the specified value?
| 0.5ohms
|
Go to Step 3
|
Go to Step 2
|
2
| Repair an open in CKT 150.
Is the repair complete?
| --
| Recheck System Operation
| --
|
3
|
- Connect the DMM between the cigar lighter connector terminal A
and ground.
- Measure the available voltage at the cigar lighter connector terminal
A .
Is the measured voltage within the specified value?
| 10.0-14.0V
|
Go to Step 5
|
Go to Step 4
|
4
| Check the C/LTR Minifuse® #7.
Is the fuse open?
| --
|
Go to Step 7
|
Go to Step 6
|
5
| Replace
the cigar lighter.
Is the repair complete?
| --
| Recheck System Operation
| --
|
6
| Repair an open in
CKT 840.
Is the repair complete?
| --
| Recheck System Operation
| --
|
7
|
- Cigar lighter disconnected.
- C/LTR Minifuse® #7 removed from instrument panel electrical
center.
- Connect a DMM between ground and the cigar lighter connector terminal
A.
- Measure CKT 840 for continuity to ground.
Is CKT 840 shorted to ground?
| --
|
Go to Step
8
|
Go to Step 5
|
8
| Repair a short to ground in CKT 840.
Is the repair complete?
| --
| Recheck System Operation
| --
|