J 39400-A Halogen Leak Detector
Note: Reposition the HVAC module rearward to access the front left-hand (LH) screw.
The front LH retaining tab of the recirculation housing is slotted.
Note: Reposition the center console wiring harness that runs beneath the HVAC module to aide in HVAC module removal.
Caution: Refer to Fastener Caution in the Preface section.
Tighten
Tighten the studs to 4 N·m (35 lb in).
Note: Ensure that the cut-outs on the dash-mat are properly aligned so that the drain and plumbing seals are seated directly against the cowl and the air inlet seal is seated directly against the dash-mat.
The opening in the dash-mat for the HVAC module drain should be aligned so that the drain opening in the cowl is approximately centered in the dash-mat opening; allowing ample room for the module drain seal to fully seat against the cowl.
Caution: Do not force the HVAC module between upper I/P and lower I/P cross vehicle beams. Damage to the HVAC module can result.
Note: Spray a light coat of 3M™ P/N 08877 Silicone Lubricant Plus or equivalent onto the HVAC module heater cover to aid in the installation process.
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
Tighten
Tighten the screw to 1.6 N·m (14 lb in).
Note: If necessary, gently rotate the HVAC module forward to engage the HVAC module studs through the corresponding holes on the cowl.
| • | The heater core block fitting |
| • | The evaporator block fitting |
| • | The HVAC module drain |
| • | The HVAC module studs |
Tighten
Tighten the bolts to 5 N·m (44 lb in).
Note: To prevent possible water leaks or wind/road noise from entering the vehicle passenger compartment, do not reuse the old HVAC module retaining and sealing nuts.
Tighten
Tighten the nuts to 10 N·m (89 lb in).
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
Tighten
Tighten the screws to 10 N·m (89 lb in).
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
Tighten
Tighten the screw to 3 N·m (27 lb in).
Tighten
Tighten the nuts to 5 N·m (44 lb in).
Note: Ensure that the evaporator drain tube is fully seated to the HVAC module.