| Table 1: | Discharge High Pressure Abnormally High | 
| Table 2: | Discharge Pressure Abnormally Low | 
| Table 3: | Suction Low Pressure Abnormally Low | 
| Table 4: | Suction Pressure Abnormally High | 
| Table 5: | Suction Pressure Abnormally High | 
| Table 6: | Suction and Discharge Pressure Abnormally High | 
| Table 7: | Suction and Discharge Pressure Abnormally Low | 
| Table 8: | Refrigerant Leaks | 
Symptom  | Checks  | Actions  | |||
|---|---|---|---|---|---|
After stopping the compressor, the pressure drops about 299 kPa (28 psi) quickly, then falls gradually  | There is air in the system.  | Recover, evacuate, and recharge the system with the specified amount of refrigerant.  | |||
The condenser is excessively hot.  | There is excessive refrigerant in the system.  | Recover, evacuate, and recharge the system with the specified amount of refrigerant.  | |||
Reduced or no airflow through the condenser.  | The condenser or the radiator fins are clogged.  | Clean the condenser or the radiator fins.  | |||
The condenser or the radiator fan is not working properly.  | 
 
  | ||||
The line to the condenser is excessively hot.  | Restricted flow of refrigerant in the system.  | Locate and repair the restriction.  | 
Symptom  | Checks  | Actions  | ||||
|---|---|---|---|---|---|---|
The condenser is not hot.  | Insufficient refrigerant in the system  | 
 
  | ||||
High and low pressures are balanced soon after stopping the compressor. Low-side pressure is higher than normal.  | Faulty compressor pressure relief valve  | Repair or replace the compressor.  | ||||
Faulty compressor seal  | ||||||
The outlet of the expansion valve is not frosted, low pressure gage indicates vacuum  | Faulty expansion valve  | Replace the expansion valve.  | ||||
Moisture in the system  | Recover, evacuate, and recharge the system.  | 
Symptom  | Checks  | Actions  | 
|---|---|---|
The condenser is not hot.  | Insufficient refrigerant in the system  | Repair the leaks. Recover, evacuate, and recharge the system.  | 
The expansion valve is not frosted and the low pressure line is not cold. The low pressure gage indicates a vacuum.  | Frozen expansion valve  | Replace the expansion valve.  | 
Faulty expansion valve  | ||
The discharge temperature is low and the air flow from the vents is restricted.  | The evaporator is frozen.  | Clear the restricted evaporator case drain.  | 
The expansion valve is frosted.  | The expansion valve is clogged.  | Clean or replace the expansion valve.  | 
The receiver/drier outlet is cool and the inlet is warm.  | The receiver/drier is clogged.  | Replace the receiver/drier.  | 
Symptom  | Checks  | Actions  | 
|---|---|---|
The low pressure hose and check joint are cooler than the temperature around the evaporator.  | The expansion valve is opened for too long.  | Replace the expansion valve.  | 
A capillary tube is loose.  | 
Symptom  | Checks  | Actions  | 
|---|---|---|
Suction pressure is lowered when the condenser is cooled by water.  | There is excessive refrigerant in the system.  | Recover, evacuate, and recharge the system.  | 
High and low pressure are equalized as soon as the compressor is stopped and both gages fluctuate while the compressor is running.  | A gasket is faulty.  | Repair or replace the compressor.  | 
The high pressure valve is faulty.  | ||
Foreign particles are stuck in the high pressure valve.  | 
Symptom  | Checks  | Actions  | |||
|---|---|---|---|---|---|
Reduced airflow through the condenser  | The condenser or the radiator fins are clogged.  | Clean the condenser and the radiator.  | |||
The radiator cooling fans are not working properly.  | 
 
  | ||||
The condenser is excessively hot.  | There is excessive refrigerant in the system.  | Recover, evacuate, and recharge the system.  | 
Symptom  | Checks  | Actions  | 
|---|---|---|
The low pressure hose and metal end areas are cooler than the evaporator.  | Clogged or kinked low pressure hose  | Repair or replace the low pressure hose.  | 
The temperature around the expansion valve is low compared to that around the receiver/dryer.  | The high pressure line is clogged.  | Repair or replace the high pressure line.  | 
Symptom  | Checks  | Actions  | 
|---|---|---|
The compressor clutch is dirty.  | The compressor shaft seal is leaking.  | Repair or replace the compressor.  | 
The compressor bolts are dirty.  | Leaking around a compressor housing bolt.  | Tighten the bolt(s) or replace the compressor.  | 
The compressor gasket is wet with oil.  | The compressor gasket is leaking.  | Repair or replace the compressor.  |