If you suspect a problem in the refrigerant system, check for the following conditions:
Perform the following hand-feel procedure to get a quick idea of whether the air conditioning (A/C) system has the proper charge of Refrigerant-134a.
°C  | °F  | kPa  | psig*  | °C  | °F  | kPa  | psig*  | 
|---|---|---|---|---|---|---|---|
-8.89  | 16  | 105.70  | 15.33  | 37.78  | 100  | 856.84  | 124.27  | 
-7.78  | 18  | 114.87  | 16.66  | 38.89  | 102  | 886.56  | 128.58  | 
-6.67  | 20  | 124.32  | 18.03  | 40.00  | 104  | 916.35  | 132.98  | 
-5.56  | 22  | 134.11  | 19.45  | 41.11  | 106  | 947.92  | 137.48  | 
-4.44  | 24  | 144.24  | 20.92  | 42.22  | 108  | 979.64  | 142.08  | 
-3.33  | 26  | 154.65  | 22.43  | 43.33  | 110  | 1012.11  | 146.79  | 
-2.22  | 28  | 165.48  | 24.00  | 44.44  | 112  | 1045.21  | 151.59  | 
-1.11  | 30  | 176.65  | 25.62  | 45.56  | 114  | 1079.14  | 156.51  | 
0.00  | 32  | 188.16  | 27.29  | 46.67  | 116  | 1113.75  | 161.53  | 
1.11  | 34  | 200.02  | 29.01  | 47.78  | 118  | 1149.12  | 166.66  | 
2.22  | 36  | 212.30  | 30.79  | 48.89  | 120  | 1185.18  | 171.89  | 
3.33  | 38  | 224.98  | 32.63  | 50.00  | 122  | 1222.07  | 177.24  | 
4.44  | 40  | 238.08  | 34.53  | 51.11  | 124  | 1259.72  | 182.70  | 
7.22  | 45  | 272.49  | 39.52  | 52.22  | 126  | 1298.12  | 188.27  | 
10.00  | 50  | 309.58  | 44.90  | 53.33  | 128  | 1337.35  | 193.96  | 
12.77  | 55  | 349.51  | 50.69  | 54.44  | 130  | 1377.35  | 199.76  | 
15.56  | 60  | 392.33  | 56.90  | 57.22  | 135  | 1480.91  | 214.78  | 
18.33  | 65  | 438.18  | 63.55  | 60.00  | 140  | 1589.57  | 230.54  | 
21.11  | 70  | 487.27  | 70.67  | 62.78  | 145  | 1703.62  | 247.08  | 
23.89  | 75  | 539.67  | 78.27  | 65.56  | 150  | 1823.04  | 264.40  | 
26.67  | 80  | 609.38  | 88.38  | 68.33  | 155  | 1948.04  | 282.53  | 
29.44  | 85  | 655.09  | 95.01  | 71.11  | 160  | 2078.77  | 301.49  | 
322.22  | 90  | 718.39  | 104.19  | 73.89  | 165  | 2215.29  | 321.29  | 
35.00  | 95  | 785.61  | 113.94  | 76.67  | 170  | 2357.81  | 341.96  | 
*All values rounded to 2 decimal places.  | |||||||
Evaporator Range: From -6.67 to -7.22°C (20 to 45°F), the temperatures represent the gas temperatures inside the coil and not on the coil surfaces. Add 1.67-5.56°C (3-10°F) the temperature for coil and air-off temperatures.
Condenser Range: From 110-160°F, to the temperatures are not ambient. Add 19.4-22.2°C (35-40°F) for proper heat transfer, and then refer to the A/C Performance Chart.
Relative Humidity  | Ambient Air Temperature  | Low Side Pressure  | Engine Speed  | Center Duct Air Temperature  | High Side Pressure  | 
|---|---|---|---|---|---|
20%  | 21°C (69.8°F)  | 110 kPa (16.0 psi)  | 2000 RPM  | 8.3°C (46.9°F)  | 1420 kPa (205.9 psi)  | 
27°C (80.6°F)  | 170 kPa (24.7 psi)  | 10.3°C (50.5°F)  | 1730 kPa (250 psi)  | ||
32°C (89.6°F)  | 200 kPa (29.0 psi)  | 13.1°C (55.6°F)  | 2,060 kPa (298.8 psi)  | ||
38°C (100.4°F)  | 220 kPa (31.9 psi)  | 16.5°C (61.7°F)  | 2110 kPa (306.0 psi)  | ||
30%  | 21°C (69.8°F)  | 110 kPa (16.0 psi)  | 2000 RPM  | 8.3°C (46.9°F)  | 1430 kPa (207.4 psi)  | 
27°C (80.6°F)  | 180 kPa (26.1 psi)  | 11.3°C (52.3°F)  | 1780 kPa (258.2 psi)  | ||
32°C (89.6°F)  | 210 kPa (30.5 psi)  | 14.3°C (57.7°F)  | 2090 kPa (303.1 psi)  | ||
38°C (100.4°F)  | 230 kPa (33.4 psi)  | 18.5°C (65.3°F)  | 2280 kPa (330.7 psi)  | ||
40%  | 21°C (69.8°F)  | 120 kPa (17.4 psi)  | 2000 RPM  | 8.4°C (47.1°F)  | 1430 kPa (207.4 psi)  | 
27°C (80.6°F)  | 180 kPa (26.1 psi)  | 12.3°C (54.1°F)  | 1820 kPa (264.0 PSI)  | ||
32°C (89.6°F)  | 210 kPa (30.5 psi)  | 15.4°C (59.7°F)  | 2170 KpA (314.7 PSI)  | ||
30°C (100.4°F)  | 240 kPa (34.8 psi)  | 20.8°C (69.4°F)  | 2390 KpA (346.6 PSI)  | ||
50%  | 21°C (69.8°F)  | 120 kPa (17.4 psi)  | 2000 RPM  | 8.4°C (47.1°F)  | 1450 kPa (210 psi)  | 
27°C (80.6°F)  | 190 kPa (27.6 psi)  | 13.3°C (55.9°F)  | 1860 kPa (269.8 psi)  | ||
32°C (89.6°F)  | 230 kPa (33.4 psi)  | 17.1°C (62.8°F)  | 2280 kPa (330.7 psi)  | ||
38°C (100.4°F)  | 250 kPa (36.3 psi)  | 22.9°C (73.2°F)  | 2490 kPa (361.1 psi)  | ||
60%  | 21°C (69.8°F)  | 130 kPa (18.9 psi)  | 2000 RPM  | 8.5°C (47.3°F)  | 1460 kPa (211.7 psi)  | 
27°C (80.6°F)  | 200 kPa (29.0 psi)  | 14.0°C (57.2°F)  | 1920 kPa (278.5 psi)  | ||
32°C (89.6°F)  | 230 kPa (33.4 psi)  | 18.0°C (64.4°F)  | 2330 kPa (337.9 psi)  | ||
38°C (100.4°F)  | 250 kPa (36.3 psi)  | 24.9°C (76.8°F)  | 2520 kPa (365.5 psi)  | ||
70%  | 21°C (69.8°F)  | 140 kPa (20.3 psi)  | 2000 RPM  | 8.5°C (47.3°F)  | 1480 kPa (214.6 psi)  | 
27°C (80.6°F)  | 210 kPa (30.5 psi)  | 15.3°C (59.5°F)  | 1970 kPa (285.7 psi)  | ||
32°C (89.6°F)  | 240 kPa (34.8 psi)  | 19.3°C (66.7°F)  | 2360 kPa (342.3 psi)  | ||
38°C (100.4°F)  | 250 kPa (36.3 psi)  | 26.7°C (80.1°F)  | 2590 kPa (375.6 psi)  | ||
80%  | 21°C (69.8°F)  | 140 kPa (20.3 psi)  | 2000 RPM  | 9.4°C (48.9°F)  | 1510 kPa (219.0 psi)  | 
27°C (80.6°F)  | 220 kPa (31.9 psi)  | 16.1°C (61.0°F)  | 2000 kPa (290.1 psi)  | ||
32°C (89.6°F)  | 240 kPa (34.8 psi)  | 20.4°C (68.7°F)  | 2420 kPa (351.0 psi)  | ||
90%  | 21°C (69.8°F)  | 160 kPa (23.2 psi)  | 2000 RPM  | 11.5°C (52.7°F)  | 1590 kPa (230.6 psi)  | 
27°C (80.6°F)  | 220 kPa (31.9 psi)  | 17.1°C (62.8°F)  | 2050 kPa (297.3 psi)  | ||
32°C (89.6°F)  | 250 kPa (36.3 psi)  | 21.7°C (71.1°F)  | 2470 kPa (358.2 psi)  |