Removal Procedure
- Loosen the air cleaner outlet duct clamp at the air cleaner assembly. 
 
- Remove the air cleaner outlet duct from the upper air cleaner assembly.
 
- Remove the upper air cleaner attachment clips.
 
- Remove the upper air cleaner cover from the lower air cleaner housing.
 
- Remove the air cleaner filter from lower air cleaner housing.
 
Installation Procedure
- Install the air cleaner filter into the lower air cleaner housing.
 
- Install the upper air cleaner cover to lower air cleaner housing.
 
- Install the upper air cleaner attachment clips.
 
Caution: Refer to Fastener Caution in the Preface section.
- Install the outlet duct to the upper air cleaner assembly with the duct clamps and tighten to 
3 N·m (27 lb in).